Simple, fast, and accurate methodology for quantitative analysis using Fourier transform infrared spectroscopy, with bio-hybrid fuel cell examples.
- 2016-03-15
- MethodsX 3
- David M Mackie
- Justin P Jahnke
- Marcus S Benyamin
- James J Sumner
- PubMed: 26977411
- DOI: 10.1016/j.mex.2016.02.002
- Low evidence
Tested successfully on real mixtures of up to nine components. We show that our methodology is robust to challenging experimental conditions such as similar substances, component percentages differing by three orders of magnitude, and imperfect (noisy) spectra.
- Effect
- Beneficial
- Effect size
- Moderate